  • Have a look at which materials we use for low-energy standardized house and how we resolve the technical details:

Insulation masonry Ytong Lambda YQ, thickness 45cm -> not needed to use EPS weatherization systems or anything else.

Ceiling construction insulation with mineral wool thickness 35 cm.

Ceiling baseplate Isover EPS Perimeter, thickness min. 7 cm.

EPS floor insulation, thickness 16 cm.

Double ceiling construction:

joints of OSB are sealed with airstop tape, self-supporting grid for gypsum board.

Plastic windows and doors Vekra Komfort EVO, triple glass filled with krypton Ug=0,5

Ceiling with an airstop tape

Detailed cross section of frame window, thickness 82 mm

Purenit – windows are embedded in this material which eliminates heat leaks

Detail of putting the window on purenit

Use of sealing tape during window installation

Detail of jamb and lintels (elimination of heat leaks)

Aluminum window sill

Detail of compactfoam with the mineral wool

Roof ending with aluminum sheets, galvanized eaves with color of the roof

Roof window VELUX MK06 -  triple glazed insulating units